Start Estrada i Studio 07 2010, Do czytania, Estrada i Studio, 2010 Estrada i Studio 07.2010, [◙◙◙◙◙ஜ۩۞۩ஜ◙◙◙◙◙ ☆E☆, Estrada I Studio Evanovich Janet - 07 - Seven Up, Janet Evanovich, Stephanie Plum Erikson Steven - Malazańska Księga Poległych 07 - Wicher smierci 01 - Imperium, Malazańska Księga Poległych Estrada i Studio 08 2010, Do czytania, Estrada i Studio, 2010 Europass - Suplement do Dyplomu Potwierdzającego Kwalifikacje Zawodowe GB, Europass - Suplement do Dyplomu Potwierdzającego Kwalifikacje Zawodowe Europa - katalog-czesci-[DE], rolnicze, •• MASZYNY rolnicze - instrukcje serwisowe itp Ergoline EXCELLENCE 700, solarium Ergoline 500,600,700,800,900 - instrukcja po polsku Ergoline Classic E 600 Manual, solarium Ergoline 500,600,700,800,900 - instrukcja po polsku EverMetal Zine 07 (13.02.2009), ZINY O MUZYCE, EverMetal Zine |
EWCM8400 8600 8900 9100 GB 07-08, Instrukcje, ELIWELL[ Pobierz całość w formacie PDF ]EWCM8400/8600/8900 • 9100 User manual Invensys Controls Europe An Invensys Company GB release 07/08 2 EWCM8400/8600/8900 • EWCM9100 CONTENTS GENERAL DESCRIPTION Characteristics... page 3 Using the manual... page 3 Warnings... page 3 AVAILABLE MODELS... page 4 INSTALLATION... page 5 Base/keyboard connection... page 5 ELECTRICAL HOOKUP PRECAUTIONS... page 6 PCInterface connection... page 6 WIRING DIAGRAMS... pages 7-10 EWCM8400 wiring diagram... page 7 EWCM8600 wiring diagram... page 8 EWCM8900 wiring diagram... page 9 EWCM9100 wiring diagram... page 10 BASIC FUNCTIONS POWER UP... page 11 KEYS AND COMPONENTS... page 11 LEDs... page 12 QUICK MENU... page 12 SHORTCUTS... pages 13-16 Keypad lock page 13 Setpoint and control band modification page 13 Reduced Menu page 13 Probes Menu page 14 Value displays page 14 Compressor/fans status page 15 Modifying the display unit of measurement page 16 Displaying and acknowledging alarms page 16 Advanced navigation page 16 ADVANCED FUNCTIONS CONFIGURING THE MACHINE... page 17 QuickStart page 17 Automatic I/O assignment pages 17-18 Manual I/O assignment page 18 COMPRESSOR CONTROL... pages 19-24 FAN CONTROL (EWCM9100)... pages 25-28 CLOCK AND TIME BANDS MENU... pages 29 FUNCTIONS MENU.. pages 30-33 Energy saving... page 30 Suction setpoint... page 31 Delivery setpoint (EWCM9100)... pages 31-32 Liquid return control... page 32 Auxiliary control... page 32 Heat recovery (EWCM9100)... page 32 Hot gas defrost... page 33 SERVICE MENU... page 33 PARAMETERS... pages 34-39 Description of administrator parameters... pages 35-39 Parameters table... pages 40-42 ALARMS... pages 43-50 Alarms log and codes list... page 45 Utility alarms table... page 46 Analogue alarms table... pages 47-48 Probe errors table... pages 49-50 USB COPYCARD... pages 51-52 KEYBOARD TECHNICAL DATA... pages 53 POWER BOARD TECHNICAL DATA... pages 53-54 Common power board technical data... page 53 EWCM8400 power board technical data... page 53 EWCM8600 power board technical data... page 54 EWCM8900 power board technical data... page 54 EWCM9100 power board technical data... page 54 PARAM MANAGER • WEBADAPTER... page 55 ACCESSORIES... page 56 PROPER AND IMPROPER USE... page 57 RESIDUAL RISKS AND RESPONSIBILITIES... page 57 LIABILITY CLAUSE... page 57 3 EWCM8400/8600/8900 • EWCM9100 Electronic controller for compressor packs on 13-Din Rail GENERAL DESCRIPTION • USING THE MANUAL • WARNINGS EWCM8400/8600/8900 • EWCM9100 13DIN are a family of controllers dedicated to the control of the machine room of a refrigeration plant, with simple, multistage or variable power compressors. Remote control • Connections for TelevisSystem or Modbus RTU remote control systems. • Display (and modification with the correct privileges) online, with an internet browser, of parameters, states and alarms. Characteristics • Up to 13 completely configurable relay outputs for controlling simple, multistage or various power compressors and condenser fans (EWCM9100). • Up to 2 analogue outputs for controlling INVERTER compressors and INVERTER fans (EWCM9100). • Up to 2 inputs with pressure transducers for the compressor section and the fan section (EWCM9100). • Up to 4 temperature inputs for NTC probes configurable as voltage free digital inputs. • Up to 10 voltage digital inputs and 4 voltage free digital inputs (EWCM9100) configurable for plant diagnostics and Energy Saving functions. • Compatibility with a vast range of refrigerants. • Built-in clock (RTC). Mounting • Mounts to 13DIN rail (power board) and panel (keypad). All machine status control and configuration can be done with the supplied LCD keypad. Menu navigation is user-friendly: two languages are available as standard (English + local language) defined according to the product code. The configuration and maintenance of the device is protected by several levels of passwords which hide/protect access for authorised persons only. The Administrator Menu is dedicated to the System Administrator and permits access to the Quick Start Menu and all configuration and operational parameters: the administrator will also manage the access passwords for the users and experts (installers and technicians). Functions • INVERTER control of compressors and fans (EWCM9100). • Proportional control, PID and Dead band. • Selection of homogenous power compressors and fan rotation policies (EWCM9100). • Algorithms for Energy Saving. • Two programmable Setpoints: normal and reduced regime. • Dynamic suction and delivery setpoints (EWCM9100). • Time band management. • Management of probe alarms and minimum and maximum pressure switch alarms both for the compressors section and for the fans section (EWCM9100). • Full alarms handling (self-diagnostics and alarms log). • Operational log handling. • Upload/download parameters, alarms log, operational logs and glossaries with USB Copy Card. • Safety system which, in case of EWCM failure, activates an alarm output to deviate machine room control to an emergency system which ensures minimum operation until technical service is possible. The Quick Start Menu is dedicated to initial configuration of the machine/system and permits quick and efficient assignment of the system’s resources. The Service Menu is typically intended for use by the Administrator and Technical Service and allows use of the Copy Card (see appropriate chapter) and utilities diagnostics and control. Any other user can, with the function keys and navigation keys, monitor the status of the system, display alarms, activate functions, etc. without the aid of passwords. The Clock and Time Bands Menu also allows the user to set the date and time and, using a weekly calendar, control the plant. IMPORTANT WARNINGS The availability and access to information is determined by the model in use and the settings made by the Administrator. The System Administrator is responsible for enabling access to the various menus for qualified staff who are charged with installing and servicing the system. The high degree of configurability of the system requires that the system and its applications be thoroughly studied for the device and system to operate at their best. Navigation and programming • User-friendly LCD graphic keyboard. • Menu navigation. • Quick access menu for immediate status display and setting main operating parameters. • Display and setting of programmable parameters in Bar, PSI, °C or °F. • Reduced set of parameters. • 3 levels of access to programming parameters. • Quick Start Menu for quick and easy configuration. • Keystroke function activation. For any doubts/information, contact Eliwell Technical Service. 4 EWCM8400/8600/8900 • EWCM9100 AVAILABLE MODELS EWCM8600 EWCM8400 6 Compressors 1 Con gurable 4 Compressors 2 Con gurable 5A SPDT 5A SPDT Relay outputs 8 Relay outputs 7 1 Alarm 8A SPDT 1 Alarm 8A SPDT INVERTER Compressor INVERTER Compressor Analogue output 1 4…20mA Analogue output 1 4…20mA 6 Compressor shut-down 1 Suction pressure switch alarm 3 Con gurable 4 Compressor shut-down 1 Suction pressure switch alarm 1 Con gurable Digital Inputs 10 High voltage Digital Inputs 6 High voltage 2 NTC 2 NTC con gured as Digital Inputs con gured as digital inputs Analogue inputs 5 2 Analogue inputs 5 2 1 4...20mA 1 4...20mA RS485 YES RS485 YES Connections Ethernet NO Connections Ethernet NO USB CopyCard YES USB CopyCard YES ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG FRE/ENG ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG FRE/ENG Menu Languages 2 Menu Languages 2 Power Supply 100-240V a Power supply 100-240Va EWCM8900 EWCM9100 4 Compressors 4 Fans 3 Con gurable 9 Compressors 2 Con gurable 5A SPDT 5A SPDT Relay outputs 13 Relay outputs 13 1 Alarm 1 Con gurable 8A SPDT 1 Alarm 1 Con gurable 8A SPDT INVERTER Compressor Analogue output 1 4…20mA 1 INVERTER Compressor 4…20mA Analogue outputs 2 9 Compressor shut-down 1 Suction pressure switch alarm 1 INVERTER fan 4…20mA Digital Inputs 10 High voltage 4 Con gurable 4 Voltage Free 2 NTC 4 Compressor shut-down 4 Fan 1 Suction pressure switch alarm 1 Discharge pressure switch alarm con gured as Digital Inputs Analogue inputs 5 2 Digital Inputs 14 1 4...20mA 10 High voltage RS485 YES Connections Ethernet NO USB CopyCard YES 4 NTC ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG FRE/ENG Analogue inputs 6 Menu Languages 2 2 4...20mA Power Supply 100-240Va RS485 YES Connections Ethernet YES (optional) USB CopyCard YES ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG FRE/ENG Menu Languages 2 Power Supply a 100-240V 5 EWCM8400/8600/8900 • EWCM9100 INSTALLATION IMPORTANT! Always make sure the device is switched OFF before operating on the connections. The operations must be carried out by qualified personnel. Do not install the devices in places subject to high humidity and/or dirt: in fact, they are suitable for use in places with normal or ordinary pollution levels. Make sure the area near the cooling slots is ventilated. Move the four spring docking devices to their standby position (use a screwdriver, see figure 3). Install the ‘BASE’ on the DIN RAIL, then press the ‘spring docking devices’ which will go to the closing position. NB: With the ‘BASE’ assembled on the DIN RAIL, the ‘Spring docking devices’ must be turned downwards. Keyboard mounting The keyboard is designed for panel-mounting. Make a 138x68mm hole. Remove the front panel (figure 1) and make 6 holes in the panel (figure 2 points A/B/C/D/E/F) of dia. 2.7 mm at the specified spacing (figure 2). Insert the device, fixing it with the screws. Close the front of the keyboard by pressing with fingers. FIG 2 - CUTout 138 Power board mounting To install the BASE on DIN RAIL, proceed as follows: A B E F FIG 1 Keyboard Mounting D C 90 150 FIG 3 CAP BASE - KEYPAD CONNECTION ELIWELL EWCM Keyboard rear For the connection between the base and the keypad, use the supplied 3 m 6-wire microfit cable. Only use the cable supplied, respecting the maximum distance of 3m. The cable must be wired separately from the power cables. max lenght 3m [ Pobierz całość w formacie PDF ] |
||||
Wszelkie Prawa Zastrzeżone! Oto smutna prawda: cierpienie uszlachetnia. Design by SZABLONY.maniak.pl. | |||||