Start
Estrada i Studio 07 2010, Do czytania, Estrada i Studio, 2010
Estrada i Studio 07.2010, [◙◙◙◙◙ஜ۩۞۩ஜ◙◙◙◙◙ ☆E☆, Estrada I Studio
Evanovich Janet - 07 - Seven Up, Janet Evanovich, Stephanie Plum
Erikson Steven - Malazańska Księga Poległych 07 - Wicher smierci 01 - Imperium, Malazańska Księga Poległych
Estrada i Studio 08 2010, Do czytania, Estrada i Studio, 2010
Europass - Suplement do Dyplomu Potwierdzającego Kwalifikacje Zawodowe GB, Europass - Suplement do Dyplomu Potwierdzającego Kwalifikacje Zawodowe
Europa - katalog-czesci-[DE], rolnicze, •• MASZYNY rolnicze - instrukcje serwisowe itp
Ergoline EXCELLENCE 700, solarium Ergoline 500,600,700,800,900 - instrukcja po polsku
Ergoline Classic E 600 Manual, solarium Ergoline 500,600,700,800,900 - instrukcja po polsku
EverMetal Zine 07 (13.02.2009), ZINY O MUZYCE, EverMetal Zine
  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • ets2.xlx.pl

  • EWCM8400 8600 8900 9100 GB 07-08, Instrukcje, ELIWELL

    [ Pobierz całość w formacie PDF ]
    EWCM8400/8600/8900 • 9100
    User manual
    Invensys Controls Europe
    An Invensys Company
    GB
    release 07/08
    2
    EWCM8400/8600/8900 • EWCM9100
    CONTENTS
    GENERAL DESCRIPTION
    Characteristics...
    page 3
    Using the manual...
    page 3
    Warnings...
    page 3
    AVAILABLE MODELS...
    page 4
    INSTALLATION...
    page 5
    Base/keyboard connection...
    page 5
    ELECTRICAL HOOKUP PRECAUTIONS...
    page 6
    PCInterface connection...
    page 6
    WIRING DIAGRAMS...
    pages 7-10
    EWCM8400 wiring diagram...
    page 7
    EWCM8600 wiring diagram...
    page 8
    EWCM8900 wiring diagram...
    page 9
    EWCM9100 wiring diagram...
    page 10
    BASIC FUNCTIONS
    POWER UP...
    page 11
    KEYS AND COMPONENTS...
    page 11
    LEDs...
    page 12
    QUICK MENU...
    page 12
    SHORTCUTS...
    pages 13-16
    Keypad lock
    page 13
    Setpoint and control band modification
    page 13
    Reduced Menu
    page 13
    Probes Menu
    page 14
    Value displays
    page 14
    Compressor/fans status
    page 15
    Modifying the display unit of measurement
    page 16
    Displaying and acknowledging alarms
    page 16
    Advanced navigation
    page 16
    ADVANCED FUNCTIONS
    CONFIGURING THE MACHINE...
    page 17
    QuickStart
    page 17
    Automatic I/O assignment
    pages 17-18
    Manual I/O assignment
    page 18
    COMPRESSOR CONTROL...
    pages 19-24
    FAN CONTROL (EWCM9100)...
    pages 25-28
    CLOCK AND TIME BANDS MENU...
    pages 29
    FUNCTIONS MENU..
    pages 30-33
    Energy saving...
    page 30
    Suction setpoint...
    page 31
    Delivery setpoint (EWCM9100)...
    pages 31-32
    Liquid return control...
    page 32
    Auxiliary control...
    page 32
    Heat recovery (EWCM9100)...
    page 32
    Hot gas defrost...
    page 33
    SERVICE MENU...
    page 33
    PARAMETERS...
    pages 34-39
    Description of administrator parameters...
    pages 35-39
    Parameters table...
    pages 40-42
    ALARMS...
    pages 43-50
    Alarms log and codes list...
    page 45
    Utility alarms table...
    page 46
    Analogue alarms table...
    pages 47-48
    Probe errors table...
    pages 49-50
    USB COPYCARD...
    pages 51-52
    KEYBOARD TECHNICAL DATA...
    pages 53
    POWER BOARD TECHNICAL DATA...
    pages 53-54
    Common power board technical data...
    page 53
    EWCM8400 power board technical data...
    page 53
    EWCM8600 power board technical data...
    page 54
    EWCM8900 power board technical data...
    page 54
    EWCM9100 power board technical data...
    page 54
    PARAM MANAGER • WEBADAPTER...
    page 55
    ACCESSORIES...
    page 56
    PROPER AND IMPROPER USE...
    page 57
    RESIDUAL RISKS AND RESPONSIBILITIES...
    page 57
    LIABILITY CLAUSE...
    page 57
     3
    EWCM8400/8600/8900 • EWCM9100
    Electronic controller for compressor packs on 13-Din Rail
    GENERAL DESCRIPTION • USING THE MANUAL • WARNINGS
    EWCM8400/8600/8900 • EWCM9100 13DIN are a family of controllers
    dedicated to the control of the machine room of a refrigeration plant, with
    simple, multistage or variable power compressors.
    Remote control
    • Connections for TelevisSystem or Modbus RTU remote control systems.
    • Display (and modification with the correct privileges) online, with an
    internet browser, of parameters, states and alarms.
    Characteristics
    • Up to 13 completely configurable relay outputs for controlling simple,
    multistage or various power compressors and condenser fans (EWCM9100).
    • Up to 2 analogue outputs for controlling
    INVERTER
    compressors and
    INVERTER
    fans (EWCM9100).
    • Up to 2 inputs with pressure transducers for the compressor section and
    the fan section (EWCM9100).
    • Up to 4 temperature inputs for NTC probes configurable as voltage free
    digital inputs.
    • Up to 10 voltage digital inputs and 4 voltage free digital inputs
    (EWCM9100) configurable for plant diagnostics and Energy Saving
    functions.
    • Compatibility with a vast range of refrigerants.
    • Built-in clock (RTC).
    Mounting
    • Mounts to 13DIN rail (power board) and panel (keypad).
    All machine status control and configuration can be done with the supplied
    LCD keypad. Menu navigation is user-friendly: two languages are available
    as standard (English + local language) defined according to the product
    code.
    The configuration and maintenance of the device is protected by several
    levels of passwords which hide/protect access for authorised persons only.
    The Administrator Menu is dedicated to the System Administrator and
    permits access to the Quick Start Menu and all configuration and
    operational parameters: the administrator will also manage the access
    passwords for the users and experts (installers and technicians).
    Functions

    INVERTER
    control of compressors and fans (EWCM9100).
    • Proportional control, PID and Dead band.
    • Selection of homogenous power compressors and fan rotation policies
    (EWCM9100).
    • Algorithms for Energy Saving.
    • Two programmable Setpoints: normal and reduced regime.
    • Dynamic suction and delivery setpoints (EWCM9100).
    • Time band management.
    • Management of probe alarms and minimum and maximum pressure
    switch alarms both for the compressors section and for the fans section
    (EWCM9100).
    • Full alarms handling (self-diagnostics and alarms log).
    • Operational log handling.
    • Upload/download parameters, alarms log, operational logs and glossaries
    with USB Copy Card.
    • Safety system which, in case of EWCM failure, activates an alarm output
    to deviate machine room control to an emergency system which ensures
    minimum operation until technical service is possible.
    The Quick Start Menu is dedicated to initial configuration of the
    machine/system and permits quick and efficient assignment of the system’s
    resources.
    The Service Menu is typically intended for use by the Administrator and
    Technical Service and allows use of the Copy Card (see appropriate
    chapter) and utilities diagnostics and control.
    Any other user can, with the function keys and navigation keys, monitor
    the status of the system, display alarms, activate functions, etc. without the
    aid of passwords.
    The Clock and Time Bands Menu also allows the user to set the date and
    time and, using a weekly calendar, control the plant.
    IMPORTANT WARNINGS
    The availability and access to information is determined by the model in
    use and the settings made by the Administrator.
    The System Administrator is responsible for enabling access to the various
    menus for qualified staff who are charged with installing and servicing the
    system.
    The high degree of configurability of the system requires that the system
    and its applications be thoroughly studied for the device and system to
    operate at their best.
    Navigation and programming
    • User-friendly LCD graphic keyboard.
    • Menu navigation.
    • Quick access menu for immediate status display and setting main
    operating parameters.
    • Display and setting of programmable parameters in Bar, PSI, °C or °F.
    • Reduced set of parameters.
    • 3 levels of access to programming parameters.
    • Quick Start Menu for quick and easy configuration.
    • Keystroke function activation.
    For any doubts/information, contact Eliwell Technical Service.
     4
    EWCM8400/8600/8900 • EWCM9100
    AVAILABLE MODELS
    EWCM8600
    EWCM8400
    6 Compressors
    1 Con
    gurable
    4 Compressors
    2 Con
    gurable
    5A SPDT
    5A SPDT
    Relay outputs
    8
    Relay outputs
    7
    1 Alarm
    8A SPDT
    1 Alarm
    8A SPDT
    INVERTER
    Compressor
    INVERTER
    Compressor
    Analogue output
    1
    4…20mA
    Analogue output
    1
    4…20mA
    6 Compressor
    shut-down
    1 Suction pressure
    switch alarm
    3 Con
    gurable
    4 Compressor
    shut-down
    1 Suction pressure
    switch alarm
    1 Con
    gurable
    Digital Inputs
    10
    High voltage
    Digital Inputs
    6
    High voltage
    2
    NTC
    2
    NTC
    con
    gured as
    Digital Inputs
    con
    gured as digital
    inputs
    Analogue inputs
    5
    2
    Analogue inputs
    5
    2
    1
    4...20mA
    1
    4...20mA
    RS485
    YES
    RS485
    YES
    Connections
    Ethernet
    NO
    Connections
    Ethernet
    NO
    USB CopyCard
    YES
    USB CopyCard
    YES
    ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG
    FRE/ENG
    ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG
    FRE/ENG
    Menu Languages
    2
    Menu Languages
    2
    Power Supply
    100-240V
    a
    Power supply
    100-240Va
    EWCM8900
    EWCM9100
    4 Compressors
    4 Fans
    3 Con
    gurable
    9 Compressors
    2 Con
    gurable
    5A SPDT
    5A SPDT
    Relay outputs
    13
    Relay outputs
    13
    1 Alarm
    1 Con
    gurable
    8A SPDT
    1 Alarm
    1 Con
    gurable
    8A SPDT
    INVERTER
    Compressor
    Analogue output
    1
    4…20mA
    1 INVERTER
    Compressor
    4…20mA
    Analogue
    outputs
    2
    9 Compressor
    shut-down
    1 Suction pressure
    switch alarm
    1 INVERTER
    fan
    4…20mA
    Digital Inputs
    10
    High voltage
    4 Con
    gurable
    4 Voltage Free
    2
    NTC
    4 Compressor
    shut-down
    4 Fan
    1 Suction pressure
    switch alarm
    1 Discharge pressure
    switch alarm
    con
    gured as
    Digital Inputs
    Analogue inputs
    5
    2
    Digital Inputs
    14
    1
    4...20mA
    10 High voltage
    RS485
    YES
    Connections
    Ethernet
    NO
    USB CopyCard
    YES
    4
    NTC
    ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG
    FRE/ENG
    Analogue inputs
    6
    Menu Languages
    2
    2
    4...20mA
    Power Supply
    100-240Va
    RS485
    YES
    Connections
    Ethernet
    YES (optional)
    USB CopyCard
    YES
    ENG/ITA - ITA/ENG - SPA/ENG - GER/ENG
    FRE/ENG
    Menu Languages
    2
    Power Supply
    a
    100-240V
     5
    EWCM8400/8600/8900 • EWCM9100
    INSTALLATION
    IMPORTANT! Always make sure the device is switched OFF before
    operating on the connections. The operations must be carried out
    by qualified personnel.
    Do not install the devices in places subject to high humidity and/or dirt:
    in fact, they are suitable for use in places with normal or ordinary
    pollution levels.
    Make sure the area near the cooling slots is ventilated.
    Move the four spring docking devices to their standby position (use a
    screwdriver, see figure 3).
    Install the ‘BASE’ on the DIN RAIL, then press the ‘spring docking devices’
    which will go to the closing position.
    NB: With the ‘BASE’ assembled on the DIN RAIL, the ‘Spring docking
    devices’ must be turned downwards.
    Keyboard mounting
    The keyboard is designed for panel-mounting.
    Make a 138x68mm hole.
    Remove the front panel (figure 1) and make 6 holes in the panel
    (figure 2 points A/B/C/D/E/F) of dia. 2.7 mm at the specified spacing
    (figure 2). Insert the device, fixing it with the screws. Close the front of
    the keyboard by pressing with fingers.
    FIG 2 - CUTout
    138
    Power board mounting
    To install the BASE on DIN RAIL, proceed as follows:
    A
    B
    E
    F
    FIG 1
    Keyboard
    Mounting
    D
    C
    90
    150
    FIG 3 CAP
    BASE - KEYPAD CONNECTION
    ELIWELL
    EWCM Keyboard
    rear
    For the connection between the base and the
    keypad, use the supplied 3 m 6-wire microfit
    cable. Only use the cable supplied, respecting the
    maximum distance of 3m.
    The cable must be wired separately from the
    power cables.
    max lenght 3m
      [ Pobierz całość w formacie PDF ]
  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • jaczytam.opx.pl
  • 
    Wszelkie Prawa Zastrzeżone! Oto smutna prawda: cierpienie uszlachetnia. Design by SZABLONY.maniak.pl.